Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Rev. Bras. Saúde Mater. Infant. (Online) ; 22(2): 349-355, Apr.-June 2022. tab, graf
Article in English | LILACS | ID: biblio-1387180

ABSTRACT

Abstract Objectives: although mortality and perinatal asphyxia in newborns have been considerably reduced, there are still deficiencies in screening and diagnosis methods for intrapartum fetal well being that aim to detect its early alterations. Therefore, the purpose of this research was to apply a methodology based on probability and entropy and confirm its capacity to detect normal and abnormal fetal cardiac dynamics from 20-minute cardiotocographic tracings. Methods: 80 cardiotocographic tracings of pregnant women in the last trimester were collected, of which the minimum and maximum fetal heart rate were evaluated every 10 seconds, as well as its repetitions along with their probability and the diagnostic S/k ratio. Finally, the statistical analysis was carried out to establish the diagnostic capacity of the method concerning the clinical evaluation and interpretation of the cardiotocographic tracing, taken as the Gold Standard. Results: it was confirmed that S/k ratio values differentiated normal from abnormal fetal cardiac dynamics with sensitivity and specificity values of 100% and a Kappa coefficient of 1. Conclusion: the applicability of a diagnostic mathematical method of cardiotocography was confirmed, which suggests its implementation in the clinical context to detect alterations in fetal well-being in 20 minutes.


Resumo Objetivos: aunque se ha logrado reducir considerablemente la mortalidad y asfixia perinatal en neonatos, aún hay deficiencias en los métodos de tamizaje y diagnóstico del bienestar fetal intraparto que detecten sus alteraciones tempranas. Por lo anterior, el propósito de esta investigación fue aplicar una metodología basada en la probabilidad y la entropía y confirmar su capacidad para diagnosticar la dinámica cardíaca fetal normal de la anormal a partir de trazados cardiotocográficos de 20 minutos. Métodos: se recolectaron 80 trazados cardiotocográficos de gestantes en el último trimestre, de los cuales se evaluaron frecuencia cardíaca fetal mínima y máxima cada 10 segundos al igual que sus repeticiones, su probabilidad y la proporción S/k diagnóstica. Finalmente, se realizó un análisis estadístico para establecer la capacidad diagnóstica del método con respecto a la interpretación el trazado cardiotocográfico y la evaluación clínica, tomadas como Gold Standard. Resultados: se confirmó que los valores de la proporción S/k diferenciaron las dinámicas cardíacas fetales normales de las anormales con valores de sensibilidad y especificidad del 100% y un coeficiente Kappa de 1. Conclusión: se confirmó la aplicabilidad de un método matemático diagnóstico de la cardiotocografía, lo cual sugiere que su implementación en la clínica para detectar alteraciones del bienestar fetal en 20 minutos.


Subject(s)
Humans , Female , Pregnancy , Pregnancy Trimester, Third , Heart Rate, Fetal , Cardiotocography/methods , Neonatal Screening , Perinatal Care , Entropy
4.
Rev. bras. ginecol. obstet ; 38(12): 589-592, Dec. 2016. tab
Article in English | LILACS | ID: biblio-843886

ABSTRACT

ABSTRACT Objective: We speculate that genetic racial disparity exists in fetal life and can be detected by modern computerized cardiotocography (cCTG) . Methods: This is a retrospective study comparing the results of the cCTG of pregnant patients at 37-42 weeks according to the parental ethnicity (black versus white). A cCTG was performed to analyze the variables of fetal heart rate (FHR). The cCTG variables analyzed were: percentage of signal loss; number of contractions; basal FHR; number of accelerations; number of decelerations; length of high variation episodes; short-term variability (STV); total trace duration time; and number of fetal active movements. Non-stress test (NST) parameters in the two groups were compared using the Mann-Whitney test for continuous data, and the Chi-square test for categorical variables. Results: We found a significantly lower number of active fetal movements (p 1/4 0.007) and longer periods of low variation (p 1/4 0.047) in the cCTG of black patients when compared with white patients. Conclusions: In conclusion, identifying the factors responsible for the variance in the objective analysis of CTG results is important to improve the outcomes of patients. Our study lends further evidence as to the importance of ethnicity in clinical cCTG interpretation.


RESUMO Objetivo: Especulamos que disparidade genética racial exist ana vida do feto, e que possa ser detectada por moderna cardiotocografia computadorizada (cCTG). Métodos: Estudo retrospective comparando resultados do cCTG de gestantes entre 37-42 semanas de gestação de acordo com etnicidade dos pais (negro vs. brancos). cCTG foi usado para analisar as variáveis a frequência cardíaca do feto (FHR). As variáveis abalizadas do cCTG foram o % de perda de sinal, número de contrações, basal FHR, número de acelerações, número de desacelerações, comprimento dos episódios de alta variação, viabilidade de curto prazo, tempo total de duração do rastreamento, e número de movimentos de atividade fetal. Os parâmetros do teste de não estresse (NST) em dois grupos foram comparados usando o teste de Mann-Whitney para dados contínuos e teste qui-square para variáveis categóricas. Resultados: Encontramos números significativamente mais baixos de movimentos de atividade fetal (p 1/4 0,007) e períodos mais longos de baixa variação (p 1/4 0,047) no cCTG de pacientes negros se comparados a pacientes brancos. Conclusões: Identificar fatores responsáveis pela variação na análise objetiva dos resultados de CTG é importante em resultados de pacientes que apresentam melhora. Nosso estudo fornece evidências adicionais à importância de estudos clínicos da etnicidade interpretada pelo cCTG.


Subject(s)
Humans , Female , Pregnancy , Black People , Cardiotocography/methods , Diagnosis, Computer-Assisted , White People , Heart Rate, Fetal/physiology , Chi-Square Distribution , Fetal Movement , Retrospective Studies , Statistics, Nonparametric
5.
Rev. bras. ginecol. obstet ; 31(12): 615-620, dez. 2009. tab
Article in Portuguese | LILACS | ID: lil-536741

ABSTRACT

OBJETIVOS: avaliar a influência dos níveis de hemoglobina (Hb) materna nos padrões da frequência cardíaca fetal (FCF) e no perfil biofísico fetal (PBF) em gestações a termo. MÉTODOS: gestantes portadoras de anemia (Hb<11,0 g/dL) foram avaliadas prospectivamente, entre a 36ª e a 40ª semana de gestação, no período compreendido entre janeiro de 2008 e março de 2009. O Grupo Controle foi constituído por gestantes de termo, saudáveis, com valores normais de hemoglobina (Hb>11,0 g/dL). Foram excluídos casos com anomalias ou restrição do crescimento fetal. A avaliação da FCF foi realizada pela cardiotocografia computadorizada (Sistema8002-Sonicaid) e análise do traçado com 30 minutos de exame. O PBF foi realizado em todas as pacientes. Foram utilizados os testes t de Student, teste do χ2 e teste exato de Fisher. O nível de significância utilizado foi de 0,05. RESULTADOS: A média da Hb materna no grupo com anemia (n=18) foi de 9,4 g/dL (DP=1,4 g/dL) e no Grupo Controle 12,4 g/dL (DP=1,3 g/dL). Quanto aos parâmetros da cardiotocografia, não foi constatada diferença significativa nas médias entre os grupos com anemia e controle, respectivamente: FCF basal (131,3 bpm versus 133,7 bpm, p=0,5), acelerações da FCF > 10 bpm (7,9 versus. 8,2, p=0,866), acelerações da FCF > 15 bpm (5,2 versus 5,4, p=0,9), episódios de alta variação da FCF (17,1 versus 15,5 min, p=0,5), episódios de baixa variação da FCF (4,4 versus 3,6 min, p=0,6), e variação de curto prazo (10,5 versus 10,9 ms, p=0,5). Em ambos os grupos, todas as pacientes apresentaram PBF normal. CONCLUSÕES: este estudo sugere que a anemia materna leve ou moderada, sem outras comorbidades maternas ou fetais, não se associa a anormalidades nos parâmetros do perfil biofísico fetal e da FCF analisada pela cardiotocografia computadorizada.


PURPOSES: to evaluate the influence of maternal hemoglobin (Hb) levels in the patterns of fetal heart rate (FHR) and in the fetal biophysical profile (FBP) in term gestations. METHODS: pregnant women with anemia (Hb<11.0 g/dL) were prospectively evaluated between the 36th and the 40th week of gestation, from January 2008 to March 2009. The Control Group was composed of term and healthy pregnant women, with normal values of hemoglobin (Hb>11,0 g/dL). Cases of anomalies or fetal growing restrictions were excluded. The FHR evaluation was performed by computerized cardiotocography (8002 System-Sonicaid), and by record analysis during 30 minutes of exam. The FBP was done in all the patients. Student's, χ2 and Fisher's exact tests were used, with 0.05 significance level. RESULTS: The average of maternal Hb in the group with anemia (n=18) was 9.4 g/dL (DP=1.4 g/dL), and in the control group, 12.4g/dL (DP=1.3 g/dL). There has been no significant mean differences between groups concerning the cardiotocography parameters, respectively: basal FHR(131.3 versus 133.7 bpm, p=0.5), FHR accelerations > 10b pm (7.9 versus 8.2, p=0.866), FHR accelerations > 15 bpm (5.2 versus. 5.4, p=0.9), episodes of high variation of the FHR (17.1 versus 15.5 min, p=0,5), episodes of variation of the FHR (4.4 versus 3.6 min, p=06), and short term variation (10.5 versus 10.9 ms, p=0.5). In both groups, all patients presented normal FBP. CONCLUSIONS: this study suggests that light or moderate maternal anemia, without other maternal or fetal comorbidity, is not associated with abnormalities in the parameters of fetal biophysical profile and of the FHR analyzed by computerized cardiotocography.


Subject(s)
Adult , Female , Humans , Pregnancy , Young Adult , Anemia , Cardiotocography , Fetus/physiology , Pregnancy Complications, Hematologic , Biophysical Phenomena , Cardiotocography/methods , Young Adult
6.
Rev. bras. ginecol. obstet ; 31(10): 513-526, out. 2009. ilus
Article in Portuguese | LILACS | ID: lil-531712

ABSTRACT

O contexto atual da atividade médica exige do obstetra e ginecologista ampla compreensão dos avanços científicos e tecnológicos de sua área. O objetivo primordial da avaliação fetal antenatal é identificar fetos de risco para eventos adversos ou para o óbito e, assim, atuar preventivamente para evitar o insucesso. O perfil biofísico fetal atinge sua máxima eficiência quando aplicado dentro do contexto clínico de cada caso. Em gestações de alto risco, a doplervelocimetria da artéria umbilical mostrou-se útil para melhorar os resultados perinatais. Na restrição de crescimento fetal por insuficiência placentária grave, antes da 34ª semana de gestação, a doplervelocimetria do ducto venoso tem sido importante instrumento na condução dos casos. Nenhum teste isoladamente é considerado o melhor na avaliação da vitalidade fetal anteparto, entretanto, a análise conjunta de todos os métodos irá propiciar melhor compreensão da resposta fetal à hipóxia.


The present context of medical practice demands from the obstetrician and gynecologist broad understanding of the scientific and technological advances of the area. The main purpose of prenatal evaluation is to identify fetuses at risk for adverse events or death, for preventive action to avoid mishappenings. The determination of fetal biophysical profile reaches its maximum efficiency when applied within the clinical context of each case. In high risk gestations, the Doppler velocimetry of the umbilical artery has shown to be useful to improve perinatal outcome. In the fetal growth deficit, due to severe placentary insufficiency, Doppler velocimetry of the venous duct has been showing to be an important tool in handling of the cases before the 34th week of gestation. Although no test itself is considered the best to evaluate the fetus's prenatal vitality, the joint analysis of all methods may lead to a better understanding of the fetal response to hypoxia.


Subject(s)
Female , Humans , Pregnancy , Fetal Monitoring , Blood Vessels , Cardiotocography/methods , Fetal Monitoring/methods , Ultrasonography, Doppler , Ultrasonography, Prenatal/methods
7.
São Paulo; s.n; 2006. [229] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-587103

ABSTRACT

Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em consequência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como frequência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para frequência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de frequência cardíaca materna...


During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine...


Subject(s)
Humans , Female , Pregnancy , Anesthesia, Local/methods , Cardiotocography/methods , Dental Restoration, Permanent , Epinephrine , Electrocardiography, Ambulatory/methods , Lidocaine , Blood Pressure Monitoring, Ambulatory/methods , Pregnancy , Rheumatic Heart Disease , Vasoconstrictor Agents
8.
Bol. méd. postgrado ; 9(2): 13-8, mayo-ago. 1993. tab
Article in Spanish | LILACS | ID: lil-159563

ABSTRACT

Se estudiaron 60 pacientes con embarazo cronológico prolongado y sin ninguna otra complicación, realizándose un monitoreo antenatal no estresante (MANE) en el servicio de estudios especiales del departamento de Gineco-Obstetricia del Hospital Central "Antonio María Pineda" en el lapso de marzo 1991 a febrero 1992 con el fin de revisar y analizar los hallazgos cardiotocográficos en busca de un patrón. Se encontró en el 53,3 por ciento frecuencia cardíaca fetal basal (FCFB) entre 120 y 135 lat/min., variabilidad I a II en el 76,6 por ciento, 3 o más movimientos fetales en el 65 por ciento, ausencia de desaceleraciones de FCFB en 58 por ciento y 3 o más ascensos transitorios de FCFB en el 50 por ciento determinando un patrón reactivo en igual proporción


Subject(s)
Pregnancy , Adolescent , Adult , Humans , Female , Cardiotocography/methods , Meconium Aspiration Syndrome , Pregnancy, Prolonged/diagnosis , Fetal Monitoring
9.
New Egyptian Journal of Medicine [The]. 1993; 9 (2): 563-7
in English | IMEMR | ID: emr-30054

ABSTRACT

High risk population at Um El-Queen Hospital were investigated with the Doppler umbilical artery FVW forms and correlated with cardiotocography and biophysical profile. There were 56 high risk patients including insulin dependent diabetes, pregnancy induced hypertension [P.I.H.], chronic hypertension, suspected intrauterine growth retardation [I.U.G.R.], and 70 control patients. 9 of high risk patients showed abnormal umbilical artery FVW values but only 3 of them showed antenatal fetal compromise. Only 5 of this 9 cases had intrauterine growth retardation [I.U.G.R.] with birth weight less than 50th centile. It is shown that umbilical artery FVW may be normal yet fetal compromise may be present or occurs shortly with possible I.U.F.D., this is more true in cases of diabetic pregnancy. There is more positive correlation between umbilical artery FVW and biophysical profile and N.S.T. in other types of high risk pregnancies including pregnancy induced hypertension growth retardation. FVW can not be relied on in diabetic pregnancy


Subject(s)
Humans , Female , Cardiotocography/methods
SELECTION OF CITATIONS
SEARCH DETAIL